Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-circulated
back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work,
if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option is not
possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal lters are required on top of its standard Aluminum
Mesh Filter set. Order according to its Part number below. The standard Aluminum Mesh Filters are intended
to capture residue from cooking and the optional charcoal lters help to purify fumes exhausted from cooking
for re-circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal fi lters, charcoal fi lter bracket and air diverter plate.
Hood Model Part No. Filters in Pkg.
ZML-M90BG/BS ZRC-00ML 2
ZML-E42BG/BS ZRC-00ML 2
1. Purchase recirculating kit per the part number above
2. Secure air diverter plate to top support frame. (FIG. H) Run 8” ducting
from top of hood and secure to air diverter plate.
3. Remove aluminum mesh fi lters from hood. Install charcoal fi lter bracket
to the inside fi lter opening. Note: screws to secure charcoal fi lter bracket
are already pre-installed in the hood and must fi rst be removed. Clip
charcoal fi lters into charcoal fi lter bracket. (FIG. H)
4. Re-install aluminum mesh fi lters.
5. Turn on charcoal fi lter change indicator on control panel (refer to details
on page 14.) The microprocessor in the controls will indicate the need
to change the charcoal fi lter after 120 hours of continuous use. Order
replacement charcoal fi lters per the list below.
Note: Refer to manual included with recirculating kit for more detailed
installation instructions.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZML-M90BG/BS Z0F-C002 2
ZML-E42BG/BS Z0F-C002 2
DO NOT WASH CHARCOAL FILTERS. Charcoal fi lters may need
to be changed more often depending on cooking habits.